1-888-525-6696
Search
Search

Ashly NXE Series 4-Channel Networkable Multi-Mode Power Amplifier with OPDAC4 & CNM-2 Cards

nXe3.04 Multi-Mode Amplifier plus CobraNet and OPDAC4 Option Cards

$7,849.00

Looking for a better price?
Start a chat with one of our reps or give us a call.
SKU nXe3.04bc Categories ,

Description

The NXE Series 4-Channel Networkable Multi-Mode Power Amplifier from Ashly comes pre-installed with OPDAC4 internal 4-channel DAC with selectable HPF and CNM-2 CobraNet Network Audio Interface cards. The Cobranet card enables access to digital audio networks at medium latencies (1.33 ms) over fast Ethernet. The amplifier is capable of driving 2 Ohms loads at full power and offers a maximum rated output power of 3000W per channel at Low Z mode, 2450W at 70V mode, and 1250W in 100V mode. In addition, the amplifier is suitable for use in performance venues, stadiums, arenas, convention centers as well as schools, store fronts, and places of worship.
The multi-mode amplifier features an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply can auto-detect 120 or 240 VAC mains, and a Neutrik powerCON is used for the AC cord. Each channel features a selectable output mode of Low Z, 70V, or 100V, an 80 Hz high-pass filter, input limiter, and input gain settings of 26 dB, 32 dB, 38 dB, or 1.4V. Each channel comes with a remote DC level control. The amplifier comes with Neutrik XLR/TRS combo jack and Euroblock input connectors and Neutrik speakON output connectors. The unit features a front panel power switch and level controls that can be disabled. The LEDs indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. In addition, the power amplifier features an Ethernet control with a real-time clock for event scheduling. The power amplifier is equipped with serial data remote control, aux preamp outputs, preset control, and fault condition logic outputs. It also features a temperature dependent variable speed forced-air cooling. In addition, the amplifier can be mounted on a standard 19” rack. Ethernet control using Protea NE software Serial data control by Ashly programmable remotes or third party controllers Aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional AES3 digital audio capability, and Dante Real-time clock with event scheduler Assign automatic execution of selected functions and tasks Event scheduler is programmed using PneS software and stored in the amplifier Ashly remote control via iPad app for custom design of secure wireless control over a network Features a switch-mode power supply that automatically detects 120 or 240 VAC operation Selectable outputs on each channel allow you to choose the desired output mode Set the DIP-switch configuration for low impedance (2, 4, and 8 Ohms), or constant voltage (70V or 100V) Ashly EMS (Energy Management System) provides an automatic sleep-mode drawing less than 1W (defeatable) Multiple internal power supplies provide increased channel separation and reliability Selectable 80 Hz hi-pass filter, limiter, and input gain per channel via rear panel Remote DC level control per channel Extensive protection circuitry and continuously variable cooling fans Ethernet port for software control and monitoring of amplifier functions with front panel COM activity LED Serial data port available for optional Ashly WR-5 and RD-8C programmable remote controls (optional RS-232 converter INA-1 available for third party controllers) Instant standby mode results in 30% reduction in idle power consumption that is triggered by contact closure, software control, or event scheduler Preset recall via contact closure, software control, remote control, or event scheduler Programmable power-on delay Aux preamp line outputs for driving other amplifiers Assignable fault condition logic outputs Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors Neutrik speakON twist locking loudspeaker connectors Neutrik powerCON detachable AC mains connectorAshly NXE3.04 Specs Channels 4 Maximum Output Power Max Output Power Per Channel, Low Impedance Output, All Channels Driven 2 Ohms: 3000 W, 4 Ohms: 2000 W, 8 Ohms: 1250 WLow Impedance Output, Bridge Mode, All Channels Driven 4 Ohms: 6000 W 8 Ohms: 4000 W70 V, 100 V Output, All Channels Driven 70 V (per channel): 2450 W 100 V (per channel): 1250 W Power Draw Total Power Draw All Channels DrivenSleep Mode: <1 W Standby Mode: 70 W Idle (no signal): 100 W Current Draw Current Draw 120 VAC Mains (divide in half for 240 V)Sleep Mode: 0.1 A Standby Mode: 1.3 A Idle (no signal): 1.85 A Maximum Current Draw All Channels Driven, Divide by 2 for 240 VAC 1/8 Maximum Power @ 2 Ohms: 29.5 A Dissipation Thermal Dissipation BTU/hr, Total for All Channels DrivenSleep Mode: <3.4 Standby Mode: 238 BTU/hr Idle (no signal): 340 BTU/hr 1/8 Maximum Power @ 2 Ohms: 2720 BTU/hr Voltage Gain Selectable at 26 dB, 32 dB, 38 dB, or 1.4 V Damping Factor >250 (8 Ohms load <1 kHz) High Pass Filter Input: 80 Hz 2nd order Distortion SMPTE, typical: <0.5% THD-N, typical: <0.5% (8 Ohms, 10 dB below rated power, 20 Hz to 20 kHz) Channel Separation -75 dB (dB from full output, 1 kHz) Signal-to-Noise Ratio 20 Hz to 20 kHz, Unweighted: >114 dB
Frequency Response 20 Hz to 20 kHz, +/-0.05 dB
Input Connector Balanced: Euroblock 3.5 mm, 1/4″ TRS and XLR combo jack
Input Impedance 10 kOhms
Maximum Input Level +21 dBu
Output Connector Speaker: Neutrik speakON
AUX: Balanced Euroblock 3.5 mm
Network Control Network: Compatible with standard 100MB Ethernet
Aux Output Level Maximum: +21 dBu
Contact Closure Remote Standby: Euroblock 3.5 mm, close contact to GND for standby mode
Preset Recall: Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
Supported Data Connections Euroblock 3.5 mm – Gnd, +18 V, In, Out
Logic Output Fault Condition: Euroblock 3.5 mm – 4 available
Level Control Remote DC: Euroblock 3.5 mm – Gnd, CV, V+ per input
Active Attenuators Per Channel: Front panel, software, offset link group, and remote
Fully Off: Mute
Amplifier Protection Inrush current limitation, temperature monitoring, output over-power protection, mains fuses
Cooling Continuously variable temperature controlled axial fan(s)
Environmental 32 to 113°F (0 to 45°C) (non-condensing)
Front Panel LED Indicators POWER (white): Switch: On, Off, Standby (flashing)
PROTECT (red): On (fault condition or shut down), Off
SLEEP (blue): On, amplifier is asleep from audio inactivity
DISABLE (yellow): On, power switch & front panel attenuators are disabled
Per Channel
CLIP/MUTE (red): Clip @ 1 dB below full output / Mute
SIGNAL (green): -18 dB below rated output
CURRENT (green): Proportional to output
TEMP (yellow): On dim at 90% max operating temperature, full bright + protect at 100%
BRIDGE (green): On, Off
Power Requirements @ 50/60 Hz
Nominal (Automatic Sensing SMPS): 120 to 240 VAC
Operating Range: 70 to 135 VAC to 140 to 270 VAC
Minimum Power-Up: 85 to 170 VAC
Power Cable Connector: 20 A powerCON
Compliance cTUVus, CE, FCC, RoHS
Dimensions 19 x 3.5 x 16.84 (483 x 89 x 428 mm)
Weight 28.7 lb (13 kg)

Additional information

Weight28.7 lbs
Dimensions19 × 3.5 × 16.84 in
Part No

See any errors on this page? Let us know